Kizlon Medical
Kizlon Medical
Kizlon Medical
Kizlon Medical

Product Category

Medical Equipment Directory

Medical Diagnostic

Surgical

Critical Care

In-Vitro Diagnostic

General Aids

In-Patient Solutions

OR Solutions

Patient Transfer Solutions

Respiratory Aids

Mobility Aids

Daily Care

Medical Consumables

Medical Disposables

All Products

Coagulation Analyser KCG-A100
Number of channels Single channel
Test parameters PT [Prothrombin Time]
APTT [Activated Partial Thromboplastin Time]
TT [Thrombin Time]
FBG [Fibrinogen Concentration]
Clotting Factors
Measurement method Photometric analysis
Display Back-illuminated LCD
Spirometer KSPM-A100
Flow range 1 L/s ⁓ 16 L/s
Volume range 10 L
Flow accuracy ± 10 %
Volume Accuracy ± 3 %
Slide Stainer KSS-A101
Reagent Containers 600 ml
Specimen slide throughput 200 specimen slides per hour
Loading capacity 3 slides rack
Number of stations 26
Diathermy Plate KDTP-A100
Conductive area 140 cm2
Type Unipolar
Use Adult
Dimension 210 mm x 105mm
Operating Table KOT-A101
Length 2100 mm
Width 480 mm
Adjustable height (Min to Max) 750 to 1000 mm
Trendelenburg ≥ 25 °
Vein Illuminator KVI-A200
Optical Technology Infrared Projection
Luminosity Range 300 lux ~ 1000 lux
Optimal Temperature 0℃ ~ 40℃
Optimal Humidity ≤ 80%
Syringe pump KSP-A100
KVO Rate 0.1 – 5ml/h (steps : 0.1ml/h)
Injection Compliance Adaptable for 5 syringe sizes
Preset Volume Range 0.1 ml – 1999.9 ml
Occlusion System 3-level alarming system
Syringe pump KSP-B100
Channel Dual channel infusion
Volume (VTBI) 0.1 ml – 1999.9 ml
Injection Compliance Adaptable for 10 syringe sizes
Accuracy ≤ ± 3 %
Dental Chair Unit KDU-A203
Memory Programs 3 Control Programs
Configuration Low-mounted
Upholstery Polyurethane
Power Voltage 220V-50Hz / 110V-60Hz
Mobile X-ray machine KMX-A100
Focal Distance 430 × 430 mm
Source Head Range 550 mm - 1820 mm
Exposure Time 0.08 s - 6.32 s
Tube Focus 2.6 x 2.6 mm
Haematology Analyser KHA-A100
Type Fully automated 3-part differential system
Throughput 60 samples/hr
Testing Parameters WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
Accuracy (CV %) WBC (109/L) : 2.0 % (7.0 - 15.0)
RBC (1012/L) : 1.5 % (3.50 - 6.00)
HGB (g/L) : 1.5 % (110 - 180)
MCV (fL) : 0.4 % (80.0 - 110.0)
PLT (109/L) : 4 % (100 - 500)
Blood and Infusion Warmer KBIW-A100
Temperature Range 37°C to 42°C
Temperature Accuracy ± 0.5°C
Warm-up Time < 45 s (20°C to 36°C)
Power Consumption 250 VA
Knee Walker Scooter KNWS-A100
Knee Pad Height range 17.5 to 22 inch
Adjustable Handle Height range 31 to 41 inch
Material Steel tubes coat with electroplates
Max Load 150 Kg
Hospital bed KHB-A211
Back-rest angle 0° - 80° (±5°)
Knee-rest angle 0° - 40° (±5°)
Construction Electrostatic powder coated S.S. tube frame and head and foot board
Load capacity 250 Kgs
Stationary X-Ray Machine KSX-A200
Exposure Voltage 50 kV ~ 100 kV
Exposure Current Small focus: 50 mA
Big focus: (50, 100, 150 and 200) mA
Max. Output Voltage 100 kV
Max. Output Current 200 mA (instant)
5 mA (running)
Hospital bed KHB-A401
Height adjustability 450 mm - 700 mm
Back-rest angle 0° - 65° (±5°)
Knee-rest angle 0° - 43° (±5°)